Volkswagen Golf Mk7 Service & Repair Manual: Refrigerant pressure and temperature sender -G395

WARNING: danger of freezing injuries — refrigerant must be extracted before removing the Volkswagen Golf Mk7 pressure/temperature sender -G395- if the circuit hasn't been evacuated.

  WARNING
Danger of freezing injuries.
If refrigerant circuit has not been evacuated, refrigerant will escape.
The refrigerant must be extracted before removing the refrigerant pressure and temperature sender -G395-. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in coolant circuit due to re-evaporation. Extract refrigerant again.
   
This refrigerant pressure and temperature sender -G395- is fitted in place of the high-pressure sender -G65- or air conditioning system pressure switch -F129-.
The pressure signal is monitored continuously, whereas the temperature signal is monitored only at temperatures greater than 0°C.
The Climatronic control unit -J255- works with this information and controls the coolant radiator fans accordingly and actuates the air conditioning system compressor regulating valve -N280-.
 

Refrigerant pressure and temperature sender -G395

    Questions & answers

    Refrigerant pressure and temperature sender -G395 — Volkswagen Golf Mk7

    What does the Golf Mk7 sender -G395- do?
    Measures both refrigerant pressure and temperature simultaneously, providing the AC control unit with data for optimising cooling efficiency and compressor protection.
    High-pressure sender -G65
    This high-pressure sender -G65- is fitted in place of the air conditioning system pressure switch -F129-. When voltage is applied to the high-pressur ...

    Air conditioner compressor regulating valve -N280
    The regulating valve is fitted to the air conditioner compressor. It is activated by the operating and display unit for Climatronic air conditioning system -E87- or t ...