VW Golf Mk7 manualsGolf Mk7 / manual

Volkswagen Golf Mk7 Service & Repair Manual: Searching for leaks in refrigerant circuits using leak detector -V.A.G 1796

Note: small leaks in a Volkswagen Golf Mk7 refrigerant circuit can be found with an electronic leak detector -V.A.G 1796- — this page requires evacuating the circuit with the AC service station first.

  Note
Small leaks can be detected with, for example, an electronic leak detector.
–  Evacuate refrigerant circuit using an air conditioner service station → Chapter.
  Note
If a larger leak is detected during the evacuation process, determine cause and rectify as described → Chapter.
If during the evacuation process no leak is detected or a very small leak is detected that but cannot be located, proceed as follows → Chapter.
Refrigerant gas is quickly dispersed by air motion. Therefore drafts must be avoided during a search for leaks.
If the refrigerant circuit is completely empty, charge with about 10% of refrigerant capacity (sticker R134a or vehicle-specific workshop manual).
Leak detection:
–  Prepare leak detector for operation according to its operating instructions.
–  Always hold probe tip under location of suspected leak.
   
If the rate of clicks rises or a howl occurs, depending on model, a leak has been found (see operating instructions for leak detector).
 

Searching for leaks in refrigerant circuits using leak detector -V.A.G 1796

    Questions & answers

    Searching for leaks in refrigerant circuits using leak detector -V.A.G 1796 — Volkswagen Golf Mk7

    How do I use the Golf Mk7 electronic leak detector?
    Evacuate and recharge the circuit. Move the detector probe slowly around all joints and fittings. An audible/visual alarm indicates R134a detection.
    Leak detection in refrigerant circuit using compressed air or nitrogen
      Note A leak in the refrigerant circuit can be detected, for example, by pressurising the circuit to a maximum of 15 bar using cleaned and dr ...

    Detecting leaks in refrigerant circuit using leak detecting system -VAS 6196- or leak detecting system -VAS 6201- or a later model
      Note Small leaks can be detected with, for example, an UV leak detector additive. –  Evacuate refrigerant circuit using a ...